Schneider Electric BMXNOE0110H
Approved changes feed: RSS · Atom
cpe:2.3:h:schneider-electric:bmxnoe0110h:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Schneider Electric (e6a779d5-aeb8-5b94-be36-761d5c05741c) |
|---|---|
| Product | Bmxnoe0110H (fcb077cc-fc06-5c53-b135-ce24070cf1fa) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2017-6017 |
not_vulnerable | 2026-06-08 05:09:50.343262 |
Details available
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
Published: 2017-06-30T02:35:00.000Z
Updated: 2024-08-05T15:18:49.611Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2015-7937 |
vulnerable | 2026-06-08 05:07:02.365817 |
Details available
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.
Published: 2015-12-21T11:00:00.000Z
Updated: 2024-08-06T08:06:30.903Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2015-6462 |
not_vulnerable | 2026-06-08 05:06:52.497830 |
Details available
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.
Published: 2019-03-21T18:44:47.000Z
Updated: 2024-08-06T07:22:21.488Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2015-6461 |
not_vulnerable | 2026-06-08 05:06:52.487521 |
Details available
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page.
Published: 2019-03-21T18:17:48.000Z
Updated: 2024-08-06T07:22:21.501Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.