Siemens CP-8050 Master Module
Approved changes feed: RSS · Atom
cpe:2.3:h:siemens:cp-8050_master_module:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Cp 8050 Master Module (9f2ee403-d499-5dc3-a411-7a8adb48d019) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2023-33921 |
not_vulnerable | 2026-06-08 06:06:23.872643 |
Details available
MEDIUM (6.8)
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The affected devices contain an exposed UART console login interface. An attacker with direct physical access could try to bruteforce or crack the root password to login to the device.
Published: 2023-06-13T08:17:20.886Z
Updated: 2025-02-13T16:55:11.752Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-33920 |
not_vulnerable | 2026-06-08 06:06:23.872000 |
Details available
MEDIUM (6.8)
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The affected devices contain the hash of the root password in a hard-coded form, which could be exploited for UART console login to the device. An attacker with direct physical access could exploit this vulnerability.
Published: 2023-06-13T08:17:19.819Z
Updated: 2025-02-13T16:55:11.191Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-33919 |
not_vulnerable | 2026-06-08 06:06:23.871372 |
Details available
HIGH (7.2)
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Published: 2023-06-13T08:17:18.755Z
Updated: 2025-11-03T20:35:33.949Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-33919 |
vulnerable | 2026-06-08 06:06:23.869125 |
Details available
HIGH (7.2)
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Published: 2023-06-13T08:17:18.755Z
Updated: 2025-11-03T20:35:33.949Z |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.