Kratos Defense & Security Solutions NGC Indoor Unit (IDU)
Approved changes feed: RSS · Atom
cpe:2.3:h:kratosdefense:ngc_indoor_unit:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Kratosdefense (7533a830-e066-52f5-ae5e-9d1c49490cd0) |
|---|---|
| Product | Ngc Indoor Unit (376b277e-518c-5e57-9346-ce347b4e1e2a) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2023-36670 |
not_vulnerable | 2026-06-08 06:08:12.847894 |
Details available
A remotely exploitable command injection vulnerability was found on the Kratos NGC-IDU 9.1.0.4. An attacker can execute arbitrary Linux commands as root by sending crafted TCP requests to the device.
Published: 2023-07-18T00:00:00.000Z
Updated: 2024-10-28T16:48:47.521Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-36670 |
vulnerable | 2026-06-08 06:08:12.846663 |
Details available
A remotely exploitable command injection vulnerability was found on the Kratos NGC-IDU 9.1.0.4. An attacker can execute arbitrary Linux commands as root by sending crafted TCP requests to the device.
Published: 2023-07-18T00:00:00.000Z
Updated: 2024-10-28T16:48:47.521Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-36669 |
not_vulnerable | 2026-06-08 06:08:12.846311 |
Details available
Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remote attackers to obtain arbitrary control of the IDU/ODU system. Any attacker with layer-3 network access to the IDU can impersonate the Touch Panel Unit (TPU) within the IDU by sending crafted TCP requests to the IDU.
Published: 2023-07-18T00:00:00.000Z
Updated: 2024-10-28T18:19:59.904Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-36669 |
vulnerable | 2026-06-08 06:08:12.845173 |
Details available
Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remote attackers to obtain arbitrary control of the IDU/ODU system. Any attacker with layer-3 network access to the IDU can impersonate the Touch Panel Unit (TPU) within the IDU by sending crafted TCP requests to the IDU.
Published: 2023-07-18T00:00:00.000Z
Updated: 2024-10-28T18:19:59.904Z |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.