Supermicro H12DGQ-NT6 FIRMWARE -
Approved changes feed: RSS · Atom
cpe:2.3:o:supermicro:h12dgq-nt6_firmware:-:*:*:*:*:*:*:*
part: o version: - update: *
| Vendor | Supermicro (32dd663f-5b71-5225-86ff-0f8b8b2807bd) |
|---|---|
| Product | H12Dgq Nt6 Firmware (0e85f978-dfe9-563a-bbba-2d7212ab47b6) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2024-36435 |
vulnerable | 2026-06-03 14:56:04.354656 |
Details available
CRITICAL (9.8)
An issue was discovered on Supermicro BMC firmware in select X11, X12, H12, B12, X13, H13, and B13 motherboards (and CMM6 modules). An unauthenticated user can post crafted data to the interface that triggers a stack buffer overflow, and may lead to arbitrary remote code execution on a BMC.
Published: 2024-07-11T00:00:00.000Z
Updated: 2024-08-02T03:37:05.220Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-35861 |
vulnerable | 2026-06-03 14:52:19.062180 |
Details available
A shell-injection vulnerability in email notifications on Supermicro motherboards (such as H12DST-B before 03.10.35) allows remote attackers to inject execute arbitrary commands as root on the BMC.
Published: 2023-07-31T00:00:00.000Z
Updated: 2024-10-22T18:08:38.401Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-34853 |
vulnerable | 2026-06-03 14:52:17.251401 |
Details available
Buffer Overflow vulnerability in Supermicro motherboard X12DPG-QR 1.4b allows local attackers to hijack control flow via manipulation of SmcSecurityEraseSetupVar variable.
Published: 2023-08-22T00:00:00.000Z
Updated: 2024-10-03T13:49:27.018Z |
Imported from gcve-enriched-dumps CVE data |
Contribute