Approved changes feed: RSS · Atom

cpe:2.3:h:rockwellautomation:panelview_plus:-:*:*:*:*:*:*:*

part: h version: - update: *

VendorRockwellautomation (483fb14e-bfe0-5dc5-b460-aca202063cba)
ProductPanelview Plus (07bfb591-a0bd-5fe6-ad2a-3535a08ce0b6)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2023-2071 not_vulnerable 2026-06-08 06:02:41.368316 FactoryTalk View Machine Edition Vulnerable to Remote Code Execution
CRITICAL (9.8)
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
Published: 2023-09-12T13:12:42.386Z
Updated: 2024-09-25T20:05:52.107Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.