Approved changes feed: RSS · Atom

cpe:2.3:h:juniper:ex4100:-:*:*:*:*:*:*:*

part: h version: - update: *

VendorJuniper (e5b3b18f-e0e0-511d-8fa5-6b210c732f6e)
ProductEx4100 (409351f8-61e3-5782-bdd1-9dfead4ce710)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2026-33781 not_vulnerable 2026-06-08 07:59:10.991826 Junos OS: EX Series, QFX Series: In a VXLAN scenario when specific control protocol packets are received, memory leaks and eventually no traffic is passed
MEDIUM (6.5)
An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on specific EX and QFX Series devices allow an unauthenticated, adjacent attacker to cause a complete Denial of Service (DoS). On EX4k, and QFX5k platforms configured as service-provider edge devices, if L2PT is enabled on the UNI and VSTP is enabled on NNI in VXLAN scenarios, receiving VSTP BPDUs on UNI leads to packet buffer allocation failures, resulting in the device to not pass traffic anymore until it is manually recovered with a restart.This issue affects Junos OS: * 24.4 releases before 24.4R2, * 25.2 releases before 25.2R1-S1, 25.2R2. This issue does not affect Junos OS releases before 24.4R1.
Published: 2026-04-09T21:35:48.123Z
Updated: 2026-04-10T14:10:08.812Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-33773 not_vulnerable 2026-06-08 07:59:10.748396 Junos OS: EX Series, QFX Series: If the same egress filter is configured on both an IRB and a physical interface one of those is not applied
MEDIUM (5.8)
An Incorrect Initialization of Resource vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on specific EX Series and QFX Series device allows an unauthenticated, network-based attacker to cause an integrity impact to downstream networks. When the same family inet or inet6 filter is applied on an IRB interface and on a physical interface as egress filter on EX4100, EX4400, EX4650 and QFX5120 devices, only one of the two filters will be applied, which can lead to traffic being sent out one of these interfaces which should have been blocked. This issue affects Junos OS on EX Series and QFX Series: * 23.4 version 23.4R2-S6, * 24.2 version 24.2R2-S3. No other Junos OS versions are affected.
Published: 2026-04-09T21:28:56.625Z
Updated: 2026-04-13T18:06:20.091Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-21910 not_vulnerable 2026-06-08 07:49:17.152730 Junos OS: EX4k Series, QFX5k Series: In an EVPN-VXLAN configuration link flaps cause Inter-VNI traffic drop
MEDIUM (6.5)
An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (PFE) of Juniper Networks Junos OS on EX4k Series and QFX5k Series platforms allows an unauthenticated network-adjacent attacker flapping an interface to cause traffic between VXLAN Network Identifiers (VNIs) to drop, leading to a Denial of Service (DoS). On all EX4k and QFX5k platforms, a link flap in an EVPN-VXLAN configuration Link Aggregation Group (LAG) results in Inter-VNI traffic dropping when there are multiple load-balanced next-hop routes for the same destination. This issue is only applicable to systems that support EVPN-VXLAN Virtual Port-Link Aggregation Groups (VPLAG), such as the QFX5110, QFX5120, QFX5200, EX4100, EX4300, EX4400, and EX4650. Service can only be restored by restarting the affected FPC via the 'request chassis fpc restart slot <slot-number>' command. This issue affects Junos OS on EX4k and QFX5k Series:  * all versions before 21.4R3-S12,  * all versions of 22.2 * from 22.4 before 22.4R3-S8,  * from 23.2 before 23.2R2-S5,  * from 23.4 before 23.4R2-S5,  * from 24.2 before 24.2R2-S3, * from 24.4 before 24.4R2.
Published: 2026-01-15T20:23:29.682Z
Updated: 2026-01-15T20:51:57.933Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-60007 not_vulnerable 2026-06-08 07:37:26.369185 Junos OS: A specifically crafted 'show chassis' command causes chassisd to crash
MEDIUM (5.5)
A NULL Pointer Dereference vulnerability in the chassis daemon (chassisd) of Juniper Networks Junos OS on MX, SRX and EX Series allows a local attacker with low privileges to cause a Denial-of-Service (DoS). When a user executes the 'show chassis' command with specifically crafted options, chassisd will crash and restart. Due to this all components but the Routing Engine (RE) in the chassis are reinitialized, which leads to a complete service outage, which the system automatically recovers from. This issue affects: Junos OS on MX, SRX and EX Series, except MX10000 Series and MX304:  * all versions before 22.4R3-S8, * 23.2 versions before 23.2R2-S5, * 23.4 versions before 23.4R2-S6, * 24.2 versions before 24.2R2-S2, * 24.4 versions before 24.4R2.
Published: 2026-01-15T20:16:22.617Z
Updated: 2026-03-16T18:18:52.683Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-30644 not_vulnerable 2026-06-08 07:17:00.865897 Junos OS: EX2300, EX3400, EX4000 Series, QFX5k Series: Receipt of a specific DHCP packet causes FPC crash when DHCP Option 82 is enabled
HIGH (7.5)
A Heap-based Buffer Overflow vulnerability in the flexible PIC concentrator (FPC) of Juniper Networks Junos OS on EX2300, EX3400, EX4100, EX4300, EX4300MP, EX4400, EX4600, EX4650-48Y, and QFX5k Series allows an attacker to send a specific DHCP packet to the device, leading to an FPC crash and restart, resulting in a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. Under a rare timing scenario outside the attacker's control, memory corruption may be observed when DHCP Option 82 is enabled, leading to an FPC crash and affecting packet forwarding. Due to the nature of the heap-based overflow, exploitation of this vulnerability could also lead to remote code execution within the FPC, resulting in complete control of the vulnerable component. This issue affects Junos OS on EX2300, EX3400, EX4100, EX4300, EX4300MP, EX4400, EX4600, EX4650-48Y, and QFX5k Series: * All versions before 21.4R3-S9,  * from 22.2 before 22.2R3-S5,  * from 22.4 before 22.4R3-S5,  * from 23.2 before 23.2R2-S3,  * from 23.4 before 23.4R2-S3,  * from 24.2 before 24.2R2.
Published: 2025-04-09T19:52:16.737Z
Updated: 2026-02-26T18:28:28.449Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-47497 not_vulnerable 2026-06-08 06:48:12.367642 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-39565 not_vulnerable 2026-06-08 06:41:51.063109 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-30388 not_vulnerable 2026-06-08 06:35:29.994829 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-21620 not_vulnerable 2026-06-08 06:27:36.211371 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-21619 not_vulnerable 2026-06-08 06:27:36.158453 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-21595 not_vulnerable 2026-06-08 06:27:35.807052 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-44203 not_vulnerable 2026-06-08 06:12:39.497656 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-44191 not_vulnerable 2026-06-08 06:12:39.263436 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data

Contribute