SIEMENS SIMATIC S7-300 CPU 314
Approved changes feed: RSS · Atom
cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Simatic S7 300 Cpu 314 (16316da8-54c6-586a-815d-9e826734ea33) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2020-15791 |
not_vulnerable | 2026-06-08 05:19:26.654298 |
Details available
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.
Published: 2020-09-09T18:13:11.000Z
Updated: 2026-06-02T18:45:29.902Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-15783 |
not_vulnerable | 2026-06-08 05:19:26.610857 |
Details available
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC TDC CPU555 (All versions), SINUMERIK 840D sl (All versions). Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port 102. A cold restart is required to recover the service.
Published: 2020-11-12T19:21:09.000Z
Updated: 2026-06-02T18:37:28.538Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2019-18336 |
not_vulnerable | 2026-06-08 05:13:11.397587 |
Details available
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published: 2020-03-10T19:16:17.000Z
Updated: 2026-06-02T18:36:21.590Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2019-10936 |
not_vulnerable | 2026-06-08 05:12:25.901005 |
Details available
HIGH (7.5)
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Published: 2019-10-10T00:00:00.000Z
Updated: 2024-08-04T22:40:15.253Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2019-10923 |
not_vulnerable | 2026-06-08 05:12:25.638869 |
Details available
HIGH (7.5)
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
Published: 2019-10-10T13:49:24.000Z
Updated: 2025-02-11T10:26:23.281Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2016-9159 |
not_vulnerable | 2026-06-08 05:08:22.836005 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2016-9158 |
not_vulnerable | 2026-06-08 05:08:22.822503 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.