Approved changes feed: RSS · Atom

cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*

part: h version: - update: *

VendorSiemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f)
ProductSimatic S7 300 Cpu 312 (f8072fcd-5401-5c88-9464-f7bbdd3b9761)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2020-15791 not_vulnerable 2026-06-08 05:19:26.654255 Details available
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.
Published: 2020-09-09T18:13:11.000Z
Updated: 2026-06-02T18:45:29.902Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-15783 not_vulnerable 2026-06-08 05:19:26.609094 Details available
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC TDC CPU555 (All versions), SINUMERIK 840D sl (All versions). Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port 102. A cold restart is required to recover the service.
Published: 2020-11-12T19:21:09.000Z
Updated: 2026-06-02T18:37:28.538Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2016-9159 not_vulnerable 2026-06-08 05:08:22.835984 Details available
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.
Published: 2016-12-17T03:34:00.000Z
Updated: 2026-06-02T20:14:08.674Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2016-9158 not_vulnerable 2026-06-08 05:08:22.821963 Details available
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system.
Published: 2016-12-17T03:34:00.000Z
Updated: 2026-06-02T18:33:29.630Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute