BINOM3 Universal Multifunctional Electric Power Quality Meter Firmware
Approved changes feed: RSS · Atom
cpe:2.3:o:binom3:universal_multifunctional_electric_power_quality_meter_firmware:-:*:*:*:*:*:*:*
part: o version: - update: *
| Vendor | Binom3 (366446f9-5489-5858-ba98-de6c7d69edc0) |
|---|---|
| Product | Universal Multifunctional Electric Power Quality Meter Firmware (d720aec0-283f-5d75-be88-cf80c50089c3) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2017-5167 |
vulnerable | 2026-06-08 05:09:39.242501 |
Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:34.832Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-5166 |
vulnerable | 2026-06-08 05:09:39.242179 |
Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:34.965Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-5165 |
vulnerable | 2026-06-08 05:09:39.241843 |
Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:34.843Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-5164 |
vulnerable | 2026-06-08 05:09:39.241487 |
Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Input sent from a malicious client is not properly verified by the server. An attacker can execute arbitrary script code in another user's browser session (CROSS-SITE SCRIPTING).
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:35.700Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-5162 |
vulnerable | 2026-06-08 05:09:39.237809 |
Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:35.398Z |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.