Approved changes feed: RSS · Atom

cpe:2.3:h:binom3:universal_multifunctional_electric_power_quality_meter:-:*:*:*:*:*:*:*

part: h version: - update: *

VendorBinom3 (366446f9-5489-5858-ba98-de6c7d69edc0)
ProductUniversal Multifunctional Electric Power Quality Meter (fb160b54-005b-5f43-b4ab-c0bd4725d3ae)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2017-5167 not_vulnerable 2026-06-08 05:09:39.242522 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:34.832Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-5166 not_vulnerable 2026-06-08 05:09:39.242200 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:34.965Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-5165 not_vulnerable 2026-06-08 05:09:39.241864 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:34.843Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-5164 not_vulnerable 2026-06-08 05:09:39.241511 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Input sent from a malicious client is not properly verified by the server. An attacker can execute arbitrary script code in another user's browser session (CROSS-SITE SCRIPTING).
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:35.700Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-5162 not_vulnerable 2026-06-08 05:09:39.238445 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:35.398Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute