Approved changes feed: RSS · Atom

cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*

part: h version: - update: *

VendorSiemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f)
ProductSimatic Cp 1616 (4467de75-c6fd-5494-a00b-dbe00d92977f)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2023-37195 not_vulnerable 2026-06-08 06:08:14.870527 Details available
MEDIUM (4.4)
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.
Published: 2023-10-10T10:21:24.004Z
Updated: 2024-09-19T14:23:36.338Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-37194 not_vulnerable 2026-06-08 06:08:14.867137 Details available
MEDIUM (6.7)
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.
Published: 2023-10-10T10:21:22.914Z
Updated: 2024-09-19T14:27:20.089Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-13946 not_vulnerable 2026-06-08 05:12:52.819023 Details available
HIGH (7.5)
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
Published: 2020-02-11T15:36:10.000Z
Updated: 2024-08-05T00:05:44.023Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-2681 not_vulnerable 2026-06-08 05:09:25.270512 Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Published: 2017-05-11T10:00:00.000Z
Updated: 2024-09-10T09:33:20.658Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-2680 not_vulnerable 2026-06-08 05:09:25.149871 Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Published: 2017-05-11T01:00:00.000Z
Updated: 2024-09-10T09:33:18.492Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute