CVE:CVE-2018-4842 not_vulnerable 2026-06-08 05:11:49.735957 Details available
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Published: 2018-06-14T00:00:00.000Z
Updated: 2024-08-05T05:18:26.218Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2018-4833 not_vulnerable 2026-06-08 05:11:49.647104 Details available
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.
Published: 2018-06-14T16:00:00.000Z
Updated: 2024-08-05T05:18:26.432Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-2681 not_vulnerable 2026-06-08 05:09:25.285517 Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Published: 2017-05-11T10:00:00.000Z
Updated: 2024-09-10T09:33:20.658Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-2680 not_vulnerable 2026-06-08 05:09:25.153598 Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Published: 2017-05-11T01:00:00.000Z
Updated: 2024-09-10T09:33:18.492Z