Siemens SINUMERIK 840D SL
Approved changes feed: RSS · Atom
cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Sinumerik 840D Sl (0d2e70ff-26aa-5ff0-839e-d1d5d3b1f680) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2020-15783 |
not_vulnerable | 2026-06-08 05:19:26.606991 |
Details available
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC TDC CPU555 (All versions), SINUMERIK 840D sl (All versions). Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port 102. A cold restart is required to recover the service.
Published: 2020-11-12T19:21:09.000Z
Updated: 2026-06-02T18:37:28.538Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2019-10936 |
vulnerable | 2026-06-08 05:12:25.833378 |
Details available
HIGH (7.5)
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Published: 2019-10-10T00:00:00.000Z
Updated: 2024-08-04T22:40:15.253Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-11464 |
not_vulnerable | 2026-06-08 05:10:38.542555 |
Details available
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published: 2018-12-12T16:00:00.000Z
Updated: 2024-08-05T08:10:14.565Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-2681 |
not_vulnerable | 2026-06-08 05:09:25.302696 |
Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Published: 2017-05-11T10:00:00.000Z
Updated: 2024-09-10T09:33:20.658Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-2680 |
not_vulnerable | 2026-06-08 05:09:25.229259 |
Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Published: 2017-05-11T01:00:00.000Z
Updated: 2024-09-10T09:33:18.492Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-12741 |
not_vulnerable | 2026-06-08 05:08:47.826212 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.