Moxa OnCell 5104-HSDPA
Approved changes feed: RSS · Atom
cpe:2.3:h:moxa:oncell_5104-hsdpa:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Moxa (98e7f712-aaf6-5b76-a35e-6cb93ba6791f) |
|---|---|
| Product | Oncell 5104 Hsdpa (e3fc1876-19c2-5ddb-a6e5-d4456832f4a3) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2017-7917 |
not_vulnerable | 2026-06-08 05:10:06.394916 |
Details available
A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device.
Published: 2017-05-29T16:00:00.000Z
Updated: 2024-08-05T16:19:29.287Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-7915 |
not_vulnerable | 2026-06-08 05:10:06.388877 |
Details available
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.
Published: 2017-05-29T16:00:00.000Z
Updated: 2024-08-05T16:19:29.342Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-7913 |
not_vulnerable | 2026-06-08 05:10:06.374577 |
Details available
A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext.
Published: 2017-05-29T16:00:00.000Z
Updated: 2024-08-05T16:19:29.494Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.