Approved changes feed: RSS · Atom

cpe:2.3:o:tenda:rx9_pro_firmware:22.03.02.20:*:*:*:*:*:*:*

part: o version: 22.03.02.20 update: *

VendorTenda (cebb1c0a-7ddd-5bf6-9fc6-52b2b4f8dd42)
ProductRx9 Pro Firmware (b87ef5ca-ed09-5f37-aab7-152c76cc94d6)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2024-10351 vulnerable 2026-06-08 06:22:04.040682 Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow
HIGH (8.8)
A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Published: 2024-10-24T23:31:11.527Z
Updated: 2024-10-25T20:50:14.294Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-10283 vulnerable 2026-06-08 06:22:03.942997 Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow
HIGH (8.8)
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Published: 2024-10-23T15:00:12.454Z
Updated: 2024-10-23T17:33:05.674Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-10282 vulnerable 2026-06-08 06:22:03.942346 Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow
HIGH (8.8)
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Published: 2024-10-23T14:31:24.051Z
Updated: 2024-10-23T17:51:56.577Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-10281 vulnerable 2026-06-08 06:22:03.941112 Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow
HIGH (8.8)
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Published: 2024-10-23T14:00:24.603Z
Updated: 2024-10-23T18:20:52.773Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.