Mediatek MT8673 Firmware
Approved changes feed: RSS · Atom
cpe:2.3:o:mediatek:mt8673_firmware:-:*:*:*:*:*:*:*
part: o version: - update: *
| Vendor | Mediatek (eceb6b1d-81fa-55a4-b2be-fe736dad9132) |
|---|---|
| Product | Mt8673 Firmware (60133b49-4960-5258-a575-d371de17b85a) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2026-20450 |
vulnerable | 2026-06-03 15:15:46.196691 |
Details available
In Modem, there is a possible system crash due to incorrect error handling. This could lead to remote denial of service, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01753620; Issue ID: MSV-6100.
Published: 2026-05-04T05:41:56.258Z
Updated: 2026-05-04T12:59:48.327Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2026-20449 |
vulnerable | 2026-06-03 15:15:46.185021 |
Details available
In Modem, there is a possible system crash due to a heap buffer overflow. This could lead to remote denial of service, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01760138; Issue ID: MSV-6148.
Published: 2026-05-04T05:41:54.581Z
Updated: 2026-05-04T12:59:15.818Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2026-20433 |
vulnerable | 2026-06-03 15:15:45.971926 |
Details available
In Modem, there is a possible out of bounds write due to a missing bounds check. This could lead to remote escalation of privilege, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is needed for exploitation. Patch ID: MOLY01088681; Issue ID: MSV-4460.
Published: 2026-04-07T03:25:32.066Z
Updated: 2026-04-08T03:55:26.543Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2026-20432 |
vulnerable | 2026-06-03 15:15:45.925272 |
Details available
In Modem, there is a possible out of bounds write due to a missing bounds check. This could lead to remote escalation of privilege, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is needed for exploitation. Patch ID: MOLY01406170; Issue ID: MSV-4461.
Published: 2026-04-07T03:25:30.263Z
Updated: 2026-04-08T03:55:25.369Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-20659 |
vulnerable | 2026-06-03 14:59:15.142717 |
Details available
In Modem, there is a possible system crash due to improper input validation. This could lead to remote denial of service, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01519028; Issue ID: MSV-2768.
Published: 2025-04-07T03:14:54.034Z
Updated: 2026-02-17T14:35:12.390Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.