WAGO 750-8207/025-000
Approved changes feed: RSS · Atom
cpe:2.3:h:wago:750-8207\/025-000:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Wago (32ab7757-de27-5378-a269-9c7ac714c35b) |
|---|---|
| Product | 750 8207/025 000 (2b50355a-c6e1-5873-8c65-8fa71f10dddc) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2023-1620 |
not_vulnerable | 2026-06-03 14:48:55.959110 |
WAGO: DoS in multiple products in multiple versions using Codesys
MEDIUM (4.9)
Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a specifically crafted packet to the CODESYS V2 runtime.
Published: 2023-06-26T06:19:30.928Z
Updated: 2024-11-12T14:11:36.673Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-1619 |
not_vulnerable | 2026-06-03 14:48:55.890356 |
WAGO: DoS in multiple versions of multiple products
MEDIUM (4.9)
Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a malformed packet.
Published: 2023-06-26T06:18:33.981Z
Updated: 2024-10-02T05:28:23.250Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-3281 |
not_vulnerable | 2026-06-03 14:47:52.778058 |
WAGO: multiple products - Loss of MAC-Address-Filtering after reboot
HIGH (7.5)
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
Published: 2022-10-17T08:20:12.389Z
Updated: 2025-05-10T02:56:32.932Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-12522 |
not_vulnerable | 2026-06-03 14:41:34.927896 |
Command Injection Vulnerability in I/O-Check Service of WAGO PFC100, PFC200 and Touch Panel 600 Series with firmware versions <=FW10
CRITICAL (10)
The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx) with firmware versions <=FW10.
Published: 2020-12-17T22:40:48.065Z
Updated: 2024-09-16T18:14:32.808Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-5459 |
not_vulnerable | 2026-06-03 14:38:57.853276 |
Details available
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.
Published: 2018-02-13T21:00:00.000Z
Updated: 2024-08-05T05:33:44.375Z Reference links |
Imported from gcve-enriched-dumps CVE data |