TOTOLINK X2000R Firmware 1.0.0-b20230726.1108
Approved changes feed: RSS · Atom
cpe:2.3:o:totolink:x2000r_firmware:1.0.0-b20230726.1108:*:*:*:*:*:*:*
part: o version: 1.0.0-b20230726.1108 update: *
| Vendor | Totolink (fa0129e6-aa24-5784-be77-22d8becdb79b) |
|---|---|
| Product | X2000R Firmware (2f4104dc-bdcf-5c93-bb35-35b131eb6cf3) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2025-5543 |
vulnerable | 2026-06-08 07:37:25.132504 |
TOTOLINK X2000R Parent Controls Page cross site scripting
LOW (2.4)
A vulnerability was found in TOTOLINK X2000R 1.0.0-B20230726.1108. It has been declared as problematic. Affected by this vulnerability is an unknown functionality of the component Parent Controls Page. The manipulation of the argument Device Name leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Published: 2025-06-03T22:31:06.988Z
Updated: 2025-06-04T13:48:10.808Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-5542 |
vulnerable | 2026-06-08 07:37:25.131819 |
TOTOLINK X2000R Virtual Server Page formPortFw cross site scripting
LOW (2.4)
A vulnerability was found in TOTOLINK X2000R 1.0.0-B20230726.1108. It has been classified as problematic. Affected is an unknown function of the file /boafrm/formPortFw of the component Virtual Server Page. The manipulation of the argument service_type leads to cross site scripting. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Published: 2025-06-03T22:00:20.144Z
Updated: 2025-06-04T13:48:49.038Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-5516 |
vulnerable | 2026-06-08 07:37:25.071870 |
TOTOLINK X2000R URL Filtering Page formFilter cross site scripting
LOW (2.4)
A vulnerability, which was classified as problematic, was found in TOTOLINK X2000R 1.0.0-B20230726.1108. This affects an unknown part of the file /boafrm/formFilter of the component URL Filtering Page. The manipulation of the argument URL Address leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2025-06-03T18:00:18.786Z
Updated: 2025-06-03T18:21:49.966Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-5515 |
vulnerable | 2026-06-08 07:37:25.071292 |
TOTOLINK X2000R formMapDel command injection
MEDIUM (6.3)
A vulnerability, which was classified as critical, has been found in TOTOLINK X2000R 1.0.0-B20230726.1108. Affected by this issue is some unknown functionality of the file /boafrm/formMapDel. The manipulation of the argument devicemac1 leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2025-06-03T17:31:08.920Z
Updated: 2025-06-03T17:52:50.972Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-5504 |
vulnerable | 2026-06-08 07:37:24.973323 |
TOTOLINK X2000R formWsc command injection
MEDIUM (6.3)
A vulnerability has been found in TOTOLINK X2000R 1.0.0-B20230726.1108 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formWsc. The manipulation of the argument peerRptPin leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2025-06-03T14:31:10.451Z
Updated: 2025-06-03T14:48:04.322Z |
Imported from gcve-enriched-dumps CVE data |
Contribute