Siemens SCALANCE M875
Approved changes feed: RSS · Atom
cpe:2.3:h:siemens:scalance_m875:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Scalance M875 (ded701b3-6dbf-55fe-bc40-b2f7ad5c13f7) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2018-11449 |
not_vulnerable | 2026-06-08 05:10:38.473235 |
Details available
A vulnerability has been identified in SCALANCE M875 (All versions). An attacker with access to the local file system might obtain passwords for administrative users. Successful exploitation requires read access to files on the local file system. A successful attack could allow an attacker to obtain administrative passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published: 2018-06-26T18:00:00.000Z
Updated: 2024-09-17T03:44:14.245Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-11448 |
not_vulnerable | 2026-06-08 05:10:38.472892 |
Details available
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published: 2018-06-26T18:00:00.000Z
Updated: 2024-09-16T16:28:54.785Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-11447 |
not_vulnerable | 2026-06-08 05:10:38.472473 |
Details available
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published: 2018-06-26T18:00:00.000Z
Updated: 2024-09-17T02:17:05.410Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.