Approved changes feed: RSS · Atom

cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:*

part: a version: * update: sp1

VendorSiemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f)
ProductSimatic Pcs7 (9f58b9ea-c182-5303-83d3-d180a082e12c)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2014-4686 vulnerable 2026-06-08 05:05:45.426039 Details available
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.
Published: 2014-07-24T14:00:00.000Z
Updated: 2024-08-06T11:27:35.236Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2014-4685 vulnerable 2026-06-08 05:05:45.425460 Details available
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
Published: 2014-07-24T14:00:00.000Z
Updated: 2024-08-06T11:27:35.335Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2014-4684 vulnerable 2026-06-08 05:05:45.424863 Details available
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.
Published: 2014-07-24T14:00:00.000Z
Updated: 2024-08-06T11:27:35.308Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2014-4683 vulnerable 2026-06-08 05:05:45.424237 Details available
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
Published: 2014-07-24T14:00:00.000Z
Updated: 2024-08-06T11:27:35.268Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2014-4682 vulnerable 2026-06-08 05:05:45.415333 Details available
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.
Published: 2014-07-24T14:00:00.000Z
Updated: 2024-08-06T11:27:35.298Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2013-3959 vulnerable 2026-06-08 05:04:33.352510 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2013-3958 vulnerable 2026-06-08 05:04:33.351834 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2013-3957 vulnerable 2026-06-08 05:04:33.346970 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.