Connected Components Workbench
Approved changes feed: RSS · Atom
cpe:2.3:a:rockwellautomation:connected_components_workbench:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Rockwellautomation (483fb14e-bfe0-5dc5-b460-aca202063cba) |
|---|---|
| Product | Connected Components Workbench (032adcef-e07b-541a-8975-ccc721837dc5) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2021-27475 |
vulnerable | 2026-06-08 05:31:21.639778 |
Rockwell Automation Connected Components Workbench Deserialization of Untrusted Data
HIGH (8.6)
Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.
Published: 2022-03-23T19:46:38.000Z
Updated: 2025-04-16T17:58:45.843Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-27473 |
vulnerable | 2026-06-08 05:31:21.638665 |
Rockwell Automation Connected Components Workbench Improper Input Validation
MEDIUM (6.1)
Rockwell Automation Connected Components Workbench v12.00.00 and prior does not sanitize paths specified within the .ccwarc archive file during extraction. This type of vulnerability is also commonly referred to as a Zip Slip. A local, authenticated attacker can create a malicious .ccwarc archive file that, when opened by Connected Components Workbench, will allow the attacker to gain the privileges of the software. If the software is running at SYSTEM level, the attacker will gain admin level privileges. User interaction is required for this exploit to be successful.
Published: 2022-03-23T19:46:36.000Z
Updated: 2025-04-16T16:38:45.599Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-27471 |
vulnerable | 2026-06-08 05:31:21.637286 |
Rockwell Automation Connected Components Workbench Path Traversal
HIGH (7.7)
The parsing mechanism that processes certain file types does not provide input sanitization for file paths. This may allow an attacker to craft malicious files that, when opened by Rockwell Automation Connected Components Workbench v12.00.00 and prior, can traverse the file system. If successfully exploited, an attacker could overwrite existing files and create additional files with the same permissions of the Connected Components Workbench software. User interaction is required for this exploit to be successful.
Published: 2022-03-23T19:46:37.000Z
Updated: 2025-04-16T17:58:57.027Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2014-5424 |
vulnerable | 2026-06-08 05:05:47.889840 |
Details available
Rockwell Automation Connected Components Workbench (CCW) before 7.00.00 allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via an invalid property value to an ActiveX control that was built with an outdated compiler.
Published: 2014-11-14T00:00:00.000Z
Updated: 2024-08-06T11:41:49.300Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute