Scalance X408 Firmware
Approved changes feed: RSS · Atom
cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*
part: o version: * update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Scalance X408 Firmware (77fa6d5c-5dc8-5e1c-a884-e5018913dd5d) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2021-29998 |
vulnerable | 2026-06-08 05:31:27.344807 |
Details available
An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client.
Published: 2021-04-13T16:16:51.000Z
Updated: 2024-08-03T22:24:59.358Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-13807 |
vulnerable | 2026-06-08 05:10:51.948472 |
Details available
A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools.
Published: 2018-09-12T14:00:00.000Z
Updated: 2024-09-17T00:37:09.724Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-2681 |
vulnerable | 2026-06-08 05:09:25.285612 |
Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Published: 2017-05-11T10:00:00.000Z
Updated: 2024-09-10T09:33:20.658Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-2680 |
vulnerable | 2026-06-08 05:09:25.156880 |
Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Published: 2017-05-11T01:00:00.000Z
Updated: 2024-09-10T09:33:18.492Z |
Imported from gcve-enriched-dumps CVE data |
Contribute