Ruggedcom Rox I All Versions
Approved changes feed: RSS · Atom
cpe:2.3:a:n/a:ruggedcom_rox_i_all_versions:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | N/A (22f567d3-1203-528c-8f0e-3eb9c2f6ca78) |
|---|---|
| Product | Ruggedcom Rox I All Versions (b3190186-d596-5305-ae87-686c7a3abbca) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2017-6864 |
vulnerable | 2026-06-08 05:09:55.040508 |
Details available
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow an authenticated user to perform stored Cross-Site Scripting attacks.
Published: 2017-03-29T01:00:00.000Z
Updated: 2024-08-05T15:41:17.697Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-2689 |
vulnerable | 2026-06-08 05:09:25.320831 |
Details available
Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings.
Published: 2017-03-29T01:00:00.000Z
Updated: 2024-08-05T14:02:07.178Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-2688 |
vulnerable | 2026-06-08 05:09:25.320480 |
Details available
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with the privileges of an authenticated user, provided the targeted user has an active session and is induced into clicking on a malicious link or into visiting a malicious website, aka CSRF.
Published: 2017-03-29T01:00:00.000Z
Updated: 2024-08-05T14:02:07.201Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-2687 |
vulnerable | 2026-06-08 05:09:25.320105 |
Details available
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link.
Published: 2017-03-29T01:00:00.000Z
Updated: 2024-08-05T14:02:07.202Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-2686 |
vulnerable | 2026-06-08 05:09:25.318708 |
Details available
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information.
Published: 2017-03-29T01:00:00.000Z
Updated: 2024-08-05T14:02:07.252Z |
Imported from gcve-enriched-dumps CVE data |
Contribute