Approved changes feed: RSS · Atom

cpe:2.3:a:n/a:binom3_electric_power_quality_meter:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorN/A (22f567d3-1203-528c-8f0e-3eb9c2f6ca78)
ProductBinom3 Electric Power Quality Meter (c81e12fc-2a30-5274-b765-2503a4efe5bc)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2017-5167 vulnerable 2026-06-08 05:09:39.242472 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:34.832Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-5166 vulnerable 2026-06-08 05:09:39.242146 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:34.965Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-5165 vulnerable 2026-06-08 05:09:39.241812 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:34.843Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-5164 vulnerable 2026-06-08 05:09:39.241446 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Input sent from a malicious client is not properly verified by the server. An attacker can execute arbitrary script code in another user's browser session (CROSS-SITE SCRIPTING).
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:35.700Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-5162 vulnerable 2026-06-08 05:09:39.237099 Details available
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
Published: 2017-02-13T21:00:00.000Z
Updated: 2024-08-05T14:55:35.398Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute