Factorytalk Activation
Approved changes feed: RSS · Atom
cpe:2.3:a:rockwellautomation:factorytalk_activation:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Rockwellautomation (483fb14e-bfe0-5dc5-b460-aca202063cba) |
|---|---|
| Product | Factorytalk Activation (bc022c8e-4349-5b07-8483-d857189b4d34) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2017-6015 |
vulnerable | 2026-06-08 05:09:50.334436 |
Details available
Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.
Published: 2018-05-11T13:00:00.000Z
Updated: 2024-09-16T21:07:54.228Z |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.