Schneider Electric Modicon Plcs
Approved changes feed: RSS · Atom
cpe:2.3:a:n/a:schneider_electric_modicon_plcs:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | N/A (22f567d3-1203-528c-8f0e-3eb9c2f6ca78) |
|---|---|
| Product | Schneider Electric Modicon Plcs (ab60439c-9cf1-57e9-8364-782c2156a446) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2017-6030 |
vulnerable | 2026-06-08 05:09:50.394514 |
Schneider Electric Modicon PLCs Predictable Value Range from Previous Values
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
Published: 2017-06-30T02:35:00.000Z
Updated: 2026-06-04T21:40:02.867Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-6028 |
vulnerable | 2026-06-08 05:09:50.391571 |
Details available
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
Published: 2017-06-30T02:35:00.000Z
Updated: 2024-08-05T15:18:49.367Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2017-6026 |
vulnerable | 2026-06-08 05:09:50.388232 |
Details available
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
Published: 2017-06-30T02:35:00.000Z
Updated: 2024-08-05T15:18:49.435Z |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.