24952 Mycarelink Monitor
Approved changes feed: RSS · Atom
cpe:2.3:a:medtronic:24952_mycarelink_monitor:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Medtronic (39ade870-5d3b-575a-9a52-512cca95c641) |
|---|---|
| Product | 24952 Mycarelink Monitor (9d9f6b38-321e-5f83-81eb-43fbf15eb16a) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2018-8870 |
vulnerable | 2026-06-08 05:12:06.627077 |
Medtronic MyCareLink Patient Monitor Use of Hard-coded Password
MEDIUM (6.4)
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.
Published: 2018-07-02T18:00:00.000Z
Updated: 2025-05-22T18:10:03.426Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-8868 |
vulnerable | 2026-06-08 05:12:06.623841 |
Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function
MEDIUM (6.2)
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.
Published: 2018-07-02T18:00:00.000Z
Updated: 2025-05-22T18:14:07.710Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-10626 |
vulnerable | 2026-06-08 05:10:35.213955 |
Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity
MEDIUM (4.4)
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An
attacker who obtains per-product credentials from the monitor and paired
implantable cardiac device information can potentially upload invalid
data to the Medtronic CareLink network.
Published: 2018-08-10T18:00:00.000Z
Updated: 2026-05-19T14:32:21.570Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-10622 |
vulnerable | 2026-06-08 05:10:35.206261 |
Medtronic MyCareLink Patient Monitor Network Credential Weakness
MEDIUM (5.2)
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.
Published: 2018-08-10T18:00:00.000Z
Updated: 2026-06-22T20:42:16.327Z Reference links |
Imported from gcve-enriched-dumps CVE data |