Approved changes feed: RSS · Atom

cpe:2.3:a:siemens_ag:sinumerik_828d_v4.7,_sinumerik_840d_sl_v4.7,_sinumerik_840d_sl_v4.8:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorSiemens Ag (6b4625df-dd28-5c6a-8569-4e99d778ef77)
ProductSinumerik 828D V4.7, Sinumerik 840D Sl V4.7, Sinumerik 840D Sl V4.8 (fa89d937-453f-5150-8520-60a15b086e1a)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2018-11464 vulnerable 2026-06-08 05:10:38.534543 Details available
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published: 2018-12-12T16:00:00.000Z
Updated: 2024-08-05T08:10:14.565Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2018-11458 vulnerable 2026-06-08 05:10:38.525615 Details available
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published: 2018-12-12T16:00:00.000Z
Updated: 2024-08-05T08:10:14.359Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2018-11457 vulnerable 2026-06-08 05:10:38.521069 Details available
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published: 2018-12-12T16:00:00.000Z
Updated: 2024-08-05T08:10:14.429Z
Reference links
Imported from gcve-enriched-dumps CVE data