Approved changes feed: RSS · Atom

cpe:2.3:a:rockwell_automation:rslinx_classic:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorRockwell Automation (dde15a4c-943a-57fe-888d-2bc03ade6545)
ProductRslinx Classic (29479216-c685-5001-9491-3b3e0d458f73)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2019-6553 vulnerable 2026-06-08 05:14:11.985241 Details available
A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition.
Published: 2019-04-04T18:59:09.000Z
Updated: 2024-08-04T20:23:21.569Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2018-14829 vulnerable 2026-06-08 05:10:53.577424 Details available
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code.
Published: 2018-09-20T20:00:00.000Z
Updated: 2024-09-16T23:12:03.232Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2018-14827 vulnerable 2026-06-08 05:10:53.576663 Details available
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality.
Published: 2018-09-20T20:00:00.000Z
Updated: 2024-09-16T19:14:30.799Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2018-14821 vulnerable 2026-06-08 05:10:53.556292 Details available
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality.
Published: 2018-09-20T20:00:00.000Z
Updated: 2024-09-17T00:35:32.767Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.