Scalance X 300 Switch Family (Incl. X408 And Siplus Net Variants)
Approved changes feed: RSS · Atom
cpe:2.3:a:siemens:scalance_x-300_switch_family_(incl._x408_and_siplus_net_variants):*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Scalance X 300 Switch Family (Incl. X408 And Siplus Net Variants) (068b265e-aa75-5b2a-a2e0-4a47f52bf0e2) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2020-28395 |
vulnerable | 2026-06-08 05:23:54.218979 |
Details available
A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
Published: 2021-01-12T00:00:00.000Z
Updated: 2024-08-04T16:33:59.028Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-15800 |
vulnerable | 2026-06-08 05:19:26.809460 |
Details available
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.
Published: 2021-01-12T20:18:33.000Z
Updated: 2024-08-04T13:30:21.877Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2019-6567 |
vulnerable | 2026-06-08 05:14:12.019306 |
Details available
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.
Published: 2019-06-12T13:47:56.000Z
Updated: 2024-08-04T20:23:22.108Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2019-13924 |
vulnerable | 2026-06-08 05:12:52.439249 |
Details available
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
Published: 2020-02-11T00:00:00.000Z
Updated: 2024-08-05T00:05:43.919Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-4848 |
vulnerable | 2026-06-08 05:11:49.798882 |
Details available
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Published: 2018-06-14T00:00:00.000Z
Updated: 2024-08-05T05:18:26.424Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2018-4842 |
vulnerable | 2026-06-08 05:11:49.734712 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.