Approved changes feed: RSS · Atom

cpe:2.3:a:rockwell_automation:compact_guardlogix_5370_controllers:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorRockwell Automation (dde15a4c-943a-57fe-888d-2bc03ade6545)
ProductCompact Guardlogix 5370 Controllers (65f8e820-4f5e-588f-a67e-3f066b555c7b)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2022-1797 vulnerable 2026-06-08 05:39:13.935982 Rockwell Automation Logix Controllers Uncontrolled Resource Consumption
MEDIUM (6.8)
A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.
Published: 2022-05-31T19:04:44.000Z
Updated: 2025-04-16T16:17:49.601Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-1161 vulnerable 2026-06-08 05:39:12.300263 ICSA-22-090-05 Rockwell Automation Logix Controllers
CRITICAL (10)
An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.
Published: 2022-04-11T19:38:14.725Z
Updated: 2025-04-16T16:31:12.359Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-6998 vulnerable 2026-06-08 05:27:11.658979 Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers Improper Input Validation
MEDIUM (5.8)
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.
Published: 2022-07-27T20:18:00.000Z
Updated: 2025-04-17T15:51:02.651Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-10954 vulnerable 2026-06-08 05:12:25.990793 Rockwell Automation CompactLogix 5370 Stack-based Buffer Overflow
An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.
Published: 2019-05-01T18:59:28.000Z
Updated: 2024-08-04T22:40:15.332Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-10952 vulnerable 2026-06-08 05:12:25.970464 Rockwell Automation CompactLogix 5370 Uncontrolled Resource Consumption
An attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.
Published: 2019-05-01T19:02:42.000Z
Updated: 2024-08-04T22:40:15.266Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.