Simatic Ipc Diagmonitor
Approved changes feed: RSS · Atom
cpe:2.3:a:siemens:simatic_ipc_diagmonitor:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Simatic Ipc Diagmonitor (62e00623-e846-549a-ab8a-d206679bcb90) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2025-23403 |
vulnerable | 2026-06-08 07:10:55.692675 |
Details available
HIGH (7)
A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures.
Published: 2025-02-11T10:29:04.193Z
Updated: 2025-04-08T08:22:26.345Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-52891 |
vulnerable | 2026-06-08 06:17:55.853070 |
Details available
MEDIUM (5.3)
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.
Published: 2024-07-09T12:04:42.619Z
Updated: 2025-08-27T20:42:53.094Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-30756 |
vulnerable | 2026-06-08 06:04:40.938528 |
Details available
MEDIUM (5.9)
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle certain errors when using the Expect HTTP request header, resulting in NULL dereference.
This could allow a remote attacker with no privileges to cause a denial of service condition in the system.
Published: 2024-09-10T09:33:40.640Z
Updated: 2024-09-10T15:10:00.273Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-30755 |
vulnerable | 2026-06-08 06:04:40.934610 |
Details available
MEDIUM (4.4)
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources.
This could allow a remote attacker with elevated privileges to cause a denial of service condition in the system.
Published: 2024-09-10T09:33:39.215Z
Updated: 2024-09-10T15:10:35.515Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-28831 |
vulnerable | 2026-06-08 06:02:36.237735 |
Details available
HIGH (7.5)
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.
This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
Published: 2023-09-12T09:32:06.153Z
Updated: 2025-11-11T20:20:09.380Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-28827 |
vulnerable | 2026-06-08 06:02:36.150660 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2019-6575 |
vulnerable | 2026-06-08 05:14:12.310543 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |