Approved changes feed: RSS · Atom

cpe:2.3:a:universal-robots:ur_software:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorUniversal Robots (9d240754-fc07-5c43-b159-22ba58ac354f)
ProductUr Software (d7573c73-21f7-5bdd-8468-91729095f4ff)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2020-10267 vulnerable 2026-06-08 05:16:35.044175 RVD#1489: Unprotected intelectual property in Universal Robots controller CB 3.1 across firmware versions
HIGH (7.5)
Universal Robots control box CB 3.1 across firmware versions (tested on 1.12.1, 1.12, 1.11 and 1.10) does not encrypt or protect in any way the intellectual property artifacts installed from the UR+ platform of hardware and software components (URCaps). These files (*.urcaps) are stored under '/root/.urcaps' as plain zip files containing all the logic to add functionality to the UR3, UR5 and UR10 robots. This flaw allows attackers with access to the robot or the robot network (while in combination with other flaws) to retrieve and easily exfiltrate all installed intellectual property.
Published: 2020-04-06T12:08:40.743Z
Updated: 2024-09-16T23:52:16.493Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-10265 vulnerable 2026-06-08 05:16:35.039129 RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions
CRITICAL (9.4)
Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization.
Published: 2020-04-06T12:08:40.665Z
Updated: 2024-09-17T03:07:51.861Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-10264 vulnerable 2026-06-08 05:16:35.034121 RTDE Interface allows unauthenticated reading of robot data and unauthenticated writing of registers and outputs
HIGH (8.8)
CB3 SW Version 3.3 and upwards, e-series SW Version 5.0 and upwards allow authenticated access to the RTDE (Real-Time Data Exchange) interface on port 30004 which allows setting registers, the speed slider fraction as well as digital and analog Outputs. Additionally unautheticated reading of robot data is also possible
Published: 2020-04-06T12:08:40.625Z
Updated: 2024-09-17T03:28:29.912Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute