Triangle Microworks Scada Data Gateway 3.02.0697 Through 4.0.122, 2.41.0213 Through 4.0.122
Approved changes feed: RSS · Atom
cpe:2.3:a:n/a:triangle_microworks_scada_data_gateway_3.02.0697_through_4.0.122,_2.41.0213_through_4.0.122:*:*:*:*:*:*:*:*part: a version: * update: *
| Vendor | N/A (22f567d3-1203-528c-8f0e-3eb9c2f6ca78) |
|---|---|
| Product | Triangle Microworks Scada Data Gateway 3.02.0697 Through 4.0.122, 2.41.0213 Through 4.0.122 (fb24434b-d3cf-5978-904a-e11fa7d48c4d) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
Notes
Imported from gcve-enriched-dumps CVE data
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2020-10615 |
vulnerable | 2026-06-08 05:16:35.389553 |
Details available
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
Published: 2020-04-15T18:28:01.000Z
Updated: 2024-08-04T11:06:10.164Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-10613 |
vulnerable | 2026-06-08 05:16:35.387531 |
Details available
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
Published: 2020-04-15T18:30:42.000Z
Updated: 2024-08-04T11:06:10.142Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-10611 |
vulnerable | 2026-06-08 05:16:35.384269 |
Details available
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
Published: 2020-04-15T18:36:16.000Z
Updated: 2024-08-04T11:06:10.007Z |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.
Inspect record JSON
Open this panel to browse, search, copy or download the JSON record.