cpe:2.3:a:philips:clinical_collaboration_platform:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorPhilips (b8a9f1cf-d82f-5e30-aade-8a8018bb7a6f)
ProductClinical Collaboration Platform (4e9f034d-9feb-5681-b9fe-b44fbbf0dadc)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2020-16247 vulnerable 2026-06-08 05:19:27.844836 Philips Clinical Collaboration Platform Configuration
MEDIUM (6.8)
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
Published: 2020-09-18T17:55:24.000Z
Updated: 2025-06-04T21:24:46.327Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-16200 vulnerable 2026-06-08 05:19:27.509604 Philips Clinical Collaboration Platform Algorithm Downgrade
MEDIUM (6.5)
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.
Published: 2020-09-18T17:53:23.000Z
Updated: 2025-06-04T21:21:08.344Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-16198 vulnerable 2026-06-08 05:19:27.506944 Philips Clinical Collaboration Platform Protection Mechanism Failure
MEDIUM (5)
When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct.
Published: 2020-09-18T17:50:08.000Z
Updated: 2025-06-04T21:17:52.555Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-14525 vulnerable 2026-06-08 05:19:23.767715 Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page
LOW (3.5)
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
Published: 2020-09-18T17:48:30.000Z
Updated: 2025-06-04T21:12:52.643Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-14506 vulnerable 2026-06-08 05:19:23.650283 Philips Clinical Collaboration Platform Cross-site Request Forgery
LOW (3.4)
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
Published: 2020-09-18T17:46:53.000Z
Updated: 2025-06-04T20:03:25.989Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute