Approved changes feed: RSS · Atom

cpe:2.3:o:siemens:simatic_s7-400_cpu_416_firmware:*:*:*:*:*:*:*:*

part: o version: * update: *

VendorSiemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f)
ProductSimatic S7 400 Cpu 416 Firmware (51f883fa-de7f-5ce9-bc7a-411164e28162)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2020-15791 vulnerable 2026-06-08 05:19:26.660417 Details available
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.
Published: 2020-09-09T18:13:11.000Z
Updated: 2026-06-02T18:45:29.902Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute