Scalance X200 4Pirt Firmware
Approved changes feed: RSS · Atom
cpe:2.3:o:siemens:scalance_x200-4pirt_firmware:*:*:*:*:*:*:*:*
part: o version: * update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Scalance X200 4Pirt Firmware (0b1e795a-2301-5a1c-84fc-f7bac4c400b0) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2020-28391 |
vulnerable | 2026-06-08 05:23:54.102741 |
Details available
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
Published: 2021-01-12T00:00:00.000Z
Updated: 2024-08-04T16:33:59.106Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-25226 |
vulnerable | 2026-06-08 05:22:36.480853 |
Details available
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.
Published: 2021-01-12T20:18:33.000Z
Updated: 2024-08-04T15:33:04.885Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-15800 |
vulnerable | 2026-06-08 05:19:26.809509 |
Details available
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.
Published: 2021-01-12T20:18:33.000Z
Updated: 2024-08-04T13:30:21.877Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-15799 |
vulnerable | 2026-06-08 05:19:26.712786 |
Details available
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.
Published: 2021-01-12T20:18:33.000Z
Updated: 2024-08-04T13:30:21.812Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute