Plc Simulator On Ecostruxureª Control Expert (Now Unity Pro) (All Versions)
Approved changes feed: RSS · Atom
cpe:2.3:a:n/a:plc_simulator_on_ecostruxureª_control_expert_(now_unity_pro)_(all_versions):*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | N/A (22f567d3-1203-528c-8f0e-3eb9c2f6ca78) |
|---|---|
| Product | Plc Simulator On Ecostruxureª Control Expert (Now Unity Pro) (All Versions) (2ee44087-1445-520c-9996-29a3f2d97a15) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2020-7559 |
vulnerable | 2026-06-08 05:27:13.543114 |
Details available
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
Published: 2020-11-19T21:04:25.000Z
Updated: 2024-08-04T09:33:19.465Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-7538 |
vulnerable | 2026-06-08 05:27:13.464718 |
Details available
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
Published: 2020-11-19T21:04:18.000Z
Updated: 2024-08-04T09:33:19.804Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-28213 |
vulnerable | 2026-06-08 05:23:53.867329 |
Details available
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.
Published: 2020-11-19T21:03:54.000Z
Updated: 2024-08-04T16:33:58.563Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-28212 |
vulnerable | 2026-06-08 05:23:53.866994 |
Details available
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.
Published: 2020-11-19T21:03:43.000Z
Updated: 2024-08-04T16:33:58.114Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-28211 |
vulnerable | 2026-06-08 05:23:53.865581 |
Details available
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.
Published: 2020-11-19T21:03:37.000Z
Updated: 2024-08-04T16:33:58.139Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.