cpe:2.3:a:mitsubishi_electric_corporation:melsec_iq-r_series:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorMitsubishi Electric Corporation (d664dc32-cd69-5fcd-bcda-db4283d1f666)
ProductMelsec Iq R Series (cf0dc546-b09d-5266-8fe3-cc0aae7f6cba)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2020-5658 vulnerable 2026-06-08 05:26:43.434084 Details available
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Published: 2020-10-30T03:35:54.000Z
Updated: 2024-08-04T08:39:25.392Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-5657 vulnerable 2026-06-08 05:26:43.432842 Details available
Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet.
Published: 2020-10-30T03:35:54.000Z
Updated: 2024-08-04T08:39:25.468Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-5656 vulnerable 2026-06-08 05:26:43.431890 Details available
Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
Published: 2020-10-30T03:35:53.000Z
Updated: 2024-08-04T08:39:25.477Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-5655 vulnerable 2026-06-08 05:26:43.430860 Details available
NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Published: 2020-10-30T03:35:53.000Z
Updated: 2024-08-04T08:39:25.490Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-5654 vulnerable 2026-06-08 05:26:43.429772 Details available
Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Published: 2020-10-30T03:35:52.000Z
Updated: 2024-08-04T08:39:25.640Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-5653 vulnerable 2026-06-08 05:26:43.423201 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data