Rockwell Factorytalk Diagnostics
Approved changes feed: RSS · Atom
cpe:2.3:a:n/a:rockwell_factorytalk_diagnostics:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | N/A (22f567d3-1203-528c-8f0e-3eb9c2f6ca78) |
|---|---|
| Product | Rockwell Factorytalk Diagnostics (9c34272d-fe07-5825-9507-9478763e3c3d) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2020-5807 |
vulnerable | 2026-06-08 05:26:43.778448 |
Details available
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.
Published: 2020-12-29T15:18:35.000Z
Updated: 2024-08-04T08:39:25.779Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.