Approved changes feed: RSS · Atom

cpe:2.3:a:n/a:rockwell_factorytalk_diagnostics:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorN/A (22f567d3-1203-528c-8f0e-3eb9c2f6ca78)
ProductRockwell Factorytalk Diagnostics (9c34272d-fe07-5825-9507-9478763e3c3d)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2020-5807 vulnerable 2026-06-08 05:26:43.778448 Details available
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.
Published: 2020-12-29T15:18:35.000Z
Updated: 2024-08-04T08:39:25.779Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.