cpe:2.3:o:rockwellautomation:controllogix_5570_firmware:*:*:*:*:*:*:*:*

part: o version: * update: *

VendorRockwellautomation (483fb14e-bfe0-5dc5-b460-aca202063cba)
ProductControllogix 5570 Firmware (3d34d01e-30b7-5d1f-a2dc-2dc93be4ac59)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2022-3157 vulnerable 2026-06-08 05:47:19.584998 Rockwell Automation GuardLogix and ControlLogix controllers Vulnerable to Denial-Of-Service Attack
HIGH (8.6)
A vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS).
Published: 2022-12-16T20:35:55.689Z
Updated: 2025-04-16T14:32:17.798Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-1797 vulnerable 2026-06-08 05:39:13.941883 Rockwell Automation Logix Controllers Uncontrolled Resource Consumption
MEDIUM (6.8)
A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.
Published: 2022-05-31T19:04:44.000Z
Updated: 2025-04-16T16:17:49.601Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-1161 vulnerable 2026-06-08 05:39:12.329139 ICSA-22-090-05 Rockwell Automation Logix Controllers
CRITICAL (10)
An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.
Published: 2022-04-11T19:38:14.725Z
Updated: 2025-04-16T16:31:12.359Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-6998 vulnerable 2026-06-08 05:27:11.668299 Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers Improper Input Validation
MEDIUM (5.8)
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.
Published: 2022-07-27T20:18:00.000Z
Updated: 2025-04-17T15:51:02.651Z
Reference links
Imported from gcve-enriched-dumps CVE data