Interactive Graphical Scada System Data Collector (Dc.Exe) (V15.0.0.21243 And Prior)
Approved changes feed: RSS · Atom
cpe:2.3:a:n/a:interactive_graphical_scada_system_data_collector_(dc.exe)_(v15.0.0.21243_and_prior):*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | N/A (22f567d3-1203-528c-8f0e-3eb9c2f6ca78) |
|---|---|
| Product | Interactive Graphical Scada System Data Collector (Dc.Exe) (V15.0.0.21243 And Prior) (d595d40b-5b4e-5a23-9911-585dd61bcd78) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2021-22805 |
vulnerable | 2026-06-08 05:30:01.470098 |
Details available
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
Published: 2022-02-11T17:40:38.000Z
Updated: 2024-08-03T18:51:07.535Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-22804 |
vulnerable | 2026-06-08 05:30:01.469814 |
Details available
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
Published: 2022-02-11T17:40:37.000Z
Updated: 2024-08-03T18:51:07.504Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-22803 |
vulnerable | 2026-06-08 05:30:01.469504 |
Details available
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
Published: 2022-02-11T17:40:36.000Z
Updated: 2024-08-03T18:51:07.457Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-22802 |
vulnerable | 2026-06-08 05:30:01.468611 |
Details available
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
Published: 2022-02-11T17:40:36.000Z
Updated: 2024-08-03T18:51:07.450Z |
Imported from gcve-enriched-dumps CVE data |
Contribute