Simatic Process Historian 2020
Approved changes feed: RSS · Atom
cpe:2.3:a:siemens:simatic_process_historian_2020:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Simatic Process Historian 2020 (5ab0ff8e-f838-54d6-8c49-c68fa636f346) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2025-30033 |
vulnerable | 2026-06-08 07:16:58.932797 |
Details available
HIGH (7.8)
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
Published: 2025-08-12T11:16:56.565Z
Updated: 2026-03-10T16:07:45.420Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2024-35783 |
vulnerable | 2026-06-08 06:39:42.762035 |
Details available
CRITICAL (9.1)
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
Published: 2024-09-10T09:36:32.225Z
Updated: 2025-01-14T10:30:01.253Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-27395 |
vulnerable | 2026-06-08 05:31:21.335202 |
Details available
A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data.
Published: 2021-10-12T09:49:20.000Z
Updated: 2024-08-03T20:48:16.821Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.