Approved changes feed: RSS · Atom

cpe:2.3:o:phoenixcontact:ilc1x0_firmware:*:*:*:*:*:*:*:*

part: o version: * update: *

VendorPhoenixcontact (ad43784c-598b-51b1-a640-9cd70ab4c265)
ProductIlc1X0 Firmware (bfc202c1-2311-5231-bff1-b3525fbcf128)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2023-46143 vulnerable 2026-06-08 06:12:44.021416 Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC
HIGH (7.5)
Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC.
Published: 2023-12-14T14:06:06.479Z
Updated: 2025-05-22T17:39:45.716Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-46141 vulnerable 2026-06-08 06:12:43.971075 Phoenix Contact: Automation Worx and classic line controllers prone to Incorrect Permission Assignment for Critical Resource
CRITICAL (9.8)
Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device.
Published: 2023-12-14T14:05:11.292Z
Updated: 2024-08-02T20:37:39.537Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-31800 vulnerable 2026-06-08 05:44:42.304103 Insufficient Verification of Data Vulnerability in PHOENIX CONTACT classic line industrial controllers
CRITICAL (9.8)
An unauthenticated, remote attacker could upload malicious logic to devices based on ProConOS/ProConOS eCLR in order to gain full control over the device.
Published: 2022-06-21T08:00:19.264Z
Updated: 2026-06-02T20:15:56.406Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-33541 vulnerable 2026-06-08 05:32:11.636780 Phoenix Contact: ILC1x Industrial controllers affected by Denial-of-Service vulnerability
HIGH (7.5)
Phoenix Contact Classic Line Controllers ILC1x0 and ILC1x1 in all versions/variants are affected by a Denial-of-Service vulnerability. The communication protocols and device access do not feature authentication measures. Remote attackers can use specially crafted IP packets to cause a denial of service on the PLC's network communication module. A successful attack stops all network communication. To restore the network connectivity the device needs to be restarted. The automation task is not affected.
Published: 2021-06-25T18:26:05.564Z
Updated: 2024-09-16T23:21:50.885Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.