Approved changes feed: RSS · Atom

cpe:2.3:o:swisslog-healthcare:hmi-3_control_panel_firmware:*:*:*:*:*:*:*:*

part: o version: * update: *

VendorSwisslog Healthcare (d0886fd9-c79f-523b-9204-ba06504c0822)
ProductHmi 3 Control Panel Firmware (2bee9c79-2807-541f-93e6-7371eb770dcd)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*

Notes

Imported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2021-37167 vulnerable 2026-06-08 05:32:53.462329 Details available
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of the functionality of the device.
Published: 2021-08-02T12:45:52.000Z
Updated: 2024-08-04T01:16:03.295Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-37166 vulnerable 2026-06-08 05:32:53.461811 Details available
A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and takes extensive time for the GUI to connect to the TCP socket, allowing the connection to be hijacked by an external attacker.
Published: 2021-08-02T12:44:43.000Z
Updated: 2024-08-04T01:16:02.369Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-37165 vulnerable 2026-06-08 05:32:53.461282 Details available
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead to remote code execution.
Published: 2021-08-02T10:48:40.000Z
Updated: 2024-08-04T01:16:03.951Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-37164 vulnerable 2026-06-08 05:32:53.460910 Details available
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a stack-based buffer overflow.
Published: 2021-08-02T12:47:50.000Z
Updated: 2024-08-04T01:16:02.556Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-37163 vulnerable 2026-06-08 05:32:53.460473 Details available
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
Published: 2021-08-02T12:46:57.000Z
Updated: 2024-08-04T01:16:03.305Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-37162 vulnerable 2026-06-08 05:32:53.460013 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-37161 vulnerable 2026-06-08 05:32:53.459437 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-37160 vulnerable 2026-06-08 05:32:53.457912 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.

Inspect record JSON

Open JSON directly

Open this panel to browse, search, copy or download the JSON record.