Cp 8022 Master Module With Gprs
Approved changes feed: RSS · Atom
cpe:2.3:a:siemens:cp-8022_master_module_with_gprs:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Cp 8022 Master Module With Gprs (215ff80d-919d-50e4-97b7-282a05f3ca5d) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2022-29884 |
vulnerable | 2026-06-08 05:42:49.566528 |
Details available
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < CPC80 V16.30), CP-8021 MASTER MODULE (All versions < CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions < CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition.
Published: 2022-07-12T10:06:40.000Z
Updated: 2024-08-03T06:33:43.055Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-46304 |
vulnerable | 2026-06-08 05:38:03.197232 |
Details available
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems.
Published: 2022-08-10T11:17:23.000Z
Updated: 2025-10-20T18:00:06.685Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-45034 |
vulnerable | 2026-06-08 05:36:47.707480 |
Details available
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links.
Published: 2022-01-11T11:27:17.000Z
Updated: 2024-08-04T04:32:13.633Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-45033 |
vulnerable | 2026-06-08 05:36:47.701448 |
Details available
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device.
Published: 2022-01-11T11:27:17.000Z
Updated: 2024-08-04T04:32:13.621Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute