Approved changes feed: RSS · Atom

cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:*:*:*:*:*:*:*:*

part: o version: * update: *

VendorRockwellautomation (483fb14e-bfe0-5dc5-b460-aca202063cba)
ProductCompact Guardlogix 5380 Firmware (df168a54-8f3e-5123-a957-9f7b0dfdb971)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2024-8626 vulnerable 2026-06-08 07:00:25.273132 Logix Controllers Vulnerable to Denial-of-Service Vulnerability
Due to a memory leak, a denial-of-service vulnerability exists in the Rockwell Automation affected products. A malicious actor could exploit this vulnerability by performing multiple actions on certain web pages of the product causing the affected products to become fully unavailable and require a power cycle to recover.
Published: 2024-10-08T16:35:04.513Z
Updated: 2024-10-08T17:36:25.719Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-3752 vulnerable 2026-06-08 05:48:22.281269 Rockwell Automation GuardLogix and ControlLogix controllers Vulnerable to Denial-Of-Service Attack
HIGH (8.6)
An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online and continue normal operation.
Published: 2022-12-19T22:23:36.836Z
Updated: 2025-04-16T14:28:03.254Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-3157 vulnerable 2026-06-08 05:47:19.583347 Rockwell Automation GuardLogix and ControlLogix controllers Vulnerable to Denial-Of-Service Attack
HIGH (8.6)
A vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS).
Published: 2022-12-16T20:35:55.689Z
Updated: 2025-04-16T14:32:17.798Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-1797 vulnerable 2026-06-08 05:39:13.936354 Rockwell Automation Logix Controllers Uncontrolled Resource Consumption
MEDIUM (6.8)
A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.
Published: 2022-05-31T19:04:44.000Z
Updated: 2025-04-16T16:17:49.601Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-1161 vulnerable 2026-06-08 05:39:12.324679 ICSA-22-090-05 Rockwell Automation Logix Controllers
CRITICAL (10)
An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.
Published: 2022-04-11T19:38:14.725Z
Updated: 2025-04-16T16:31:12.359Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-1159 vulnerable 2026-06-08 05:39:12.289233 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.