Approved changes feed: RSS · Atom
cpe:2.3:a:yokogawa_electric_corporation:centum_vp:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Yokogawa Electric Corporation (10a78483-1734-5175-a349-0d9bf91589eb) |
|---|---|
| Product | Centum Vp (bf5515f6-78cd-54b7-a0bf-46121ed9f465) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2025-7741 |
vulnerable | 2026-06-03 15:13:41.361172 |
Details available
Hardcoded Password Vulnerability have been found in CENTUM. Affected products contain a hardcoded password for the user account (PROG) used for CENTUM Authentication Mode within the system. Under the following conditions, there is a risk that an attacker could log in as the PROG user.
The default permission for the PROG users is S1 permission (equivalent to OFFUSER). Therefore, for properly permission-controlled targets of operation and monitoring, even if an attacker user in as the PROG user, the risk of critical operations or configuration changes being performed is considered low. (If the PROG user's permissions have been changed for any reason, there is a risk that operations or configuration changes may be performed under the modified permissions. The CVSS values below are for the default permissions.)
Additionally, exploiting this vulnerability requires an attacker to already have access to the HIS screen controls. Therefore, an attacker can already operate and monitor at that point, regardless of this vulnerability.
The conditions under which this vulnerability is exploited:
If all of the following conditions are met, the affected products are vulnerable to this vulnerability.
-An attacker obtains the hardcoded password using a certain method.
-The HIS with the affected product installed is configured in CTM authentication mode.
-An attacker must have direct access to the aforementioned HIS or be able to break into it remotely using a certain method and perform screen operations.
The affected products and versions are as follows: CENTUM VP R5.01.00 to R5.04.20, R6.01.00 to R6.12.00 and R7.01.00.
Published: 2026-03-30T00:01:11.948Z
Updated: 2026-03-30T15:03:00.408Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2024-5650 |
vulnerable | 2026-06-03 14:57:53.636890 |
Details available
HIGH (8.5)
DLL Hijacking vulnerability has been found in CENTUM CAMS Log server provided by Yokogawa Electric Corporation. If an attacker is somehow able to intrude into a computer that installed affected product or access to a shared folder, by replacing the DLL file with a tampered one, it is possible to execute arbitrary programs with the authority of the SYSTEM account.
The affected products and versions are as follows:
CENTUM CS 3000 R3.08.10 to R3.09.50
CENTUM VP R4.01.00 to R4.03.00, R5.01.00 to R5.04.20, R6.01.00 to R6.11.10.
Published: 2024-06-17T06:21:31.387Z
Updated: 2024-08-01T21:18:06.883Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-23402 |
vulnerable | 2026-06-03 14:46:27.071356 |
Details available
The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00
Published: 2022-03-11T09:10:53.000Z
Updated: 2024-08-03T03:43:45.995Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-23401 |
vulnerable | 2026-06-03 14:46:27.070793 |
Details available
The following Yokogawa Electric products contain insecure DLL loading issues. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
Published: 2022-03-11T09:10:51.000Z
Updated: 2024-08-03T03:43:45.875Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-22729 |
vulnerable | 2026-06-03 14:46:25.294085 |
Details available
CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.
Published: 2022-03-11T09:10:50.000Z
Updated: 2024-08-03T03:21:49.121Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-22151 |
vulnerable | 2026-06-03 14:46:16.838606 |
Details available
CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.
Published: 2022-03-11T09:10:48.000Z
Updated: 2024-08-03T03:07:48.306Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-22148 |
vulnerable | 2026-06-03 14:46:16.830205 |
Details available
'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
Published: 2022-03-11T09:10:47.000Z
Updated: 2024-08-03T03:07:49.688Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-22145 |
vulnerable | 2026-06-03 14:46:16.829291 |
Details available
CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource consumption. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
Published: 2022-03-11T09:10:45.000Z
Updated: 2024-08-03T03:07:48.938Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-22141 |
vulnerable | 2026-06-03 14:46:16.827620 |
Details available
'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
Published: 2022-03-11T09:10:44.000Z
Updated: 2024-08-03T03:07:48.318Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-21808 |
vulnerable | 2026-06-03 14:46:13.787911 |
Details available
Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
Published: 2022-03-11T09:10:42.000Z
Updated: 2024-08-03T02:53:36.258Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-21194 |
vulnerable | 2026-06-03 14:46:11.705302 |
Details available
The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00.
Published: 2022-03-11T09:10:41.000Z
Updated: 2024-08-03T02:31:59.724Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-21177 |
vulnerable | 2026-06-03 14:46:11.379601 |
Details available
There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, andfrom R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
Published: 2022-03-11T09:10:39.000Z
Updated: 2024-08-03T02:31:59.257Z |
Imported from gcve-enriched-dumps CVE data |