Simatic Energy Manager Basic
Approved changes feed: RSS · Atom
cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*
part: a version: 7.3 update: -
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Simatic Energy Manager Basic (87dcda6e-eede-5291-9ee8-72ddd41a4ca5) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2022-23450 |
vulnerable | 2026-06-08 05:40:57.549435 |
Details available
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
Published: 2022-04-12T09:07:38.000Z
Updated: 2024-08-03T03:43:45.971Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-23449 |
vulnerable | 2026-06-08 05:40:57.548902 |
Details available
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
Published: 2022-04-12T09:07:37.000Z
Updated: 2024-08-03T03:43:45.997Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-23448 |
vulnerable | 2026-06-08 05:40:57.547781 |
Details available
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
Published: 2022-04-12T09:07:35.000Z
Updated: 2024-08-03T03:43:45.944Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.