cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_server:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorSchneider Electric (e6a779d5-aeb8-5b94-be36-761d5c05741c)
ProductInteractive Graphical Scada System Data Server (d9fdae95-addb-5b2d-8954-2691c7a5d555)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2022-24317 vulnerable 2026-06-08 05:41:00.138344 Details available
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:05:03.000Z
Updated: 2024-08-03T04:07:02.387Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-24316 vulnerable 2026-06-08 05:41:00.137948 Details available
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:05:02.000Z
Updated: 2024-08-03T04:07:02.318Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-24315 vulnerable 2026-06-08 05:41:00.137650 Details available
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:05:01.000Z
Updated: 2024-08-03T04:07:02.404Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-24314 vulnerable 2026-06-08 05:41:00.137348 Details available
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:05:00.000Z
Updated: 2024-08-03T04:07:02.443Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-24313 vulnerable 2026-06-08 05:41:00.137059 Details available
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:04:59.000Z
Updated: 2024-08-03T04:07:02.386Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-24312 vulnerable 2026-06-08 05:41:00.136761 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-24311 vulnerable 2026-06-08 05:41:00.136435 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-24310 vulnerable 2026-06-08 05:41:00.136012 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data