Interactive Graphical Scada System Data Server
Approved changes feed: RSS · Atom
cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_server:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Schneider Electric (e6a779d5-aeb8-5b94-be36-761d5c05741c) |
|---|---|
| Product | Interactive Graphical Scada System Data Server (d9fdae95-addb-5b2d-8954-2691c7a5d555) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2022-24317 |
vulnerable | 2026-06-08 05:41:00.138344 |
Details available
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:05:03.000Z
Updated: 2024-08-03T04:07:02.387Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-24316 |
vulnerable | 2026-06-08 05:41:00.137948 |
Details available
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:05:02.000Z
Updated: 2024-08-03T04:07:02.318Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-24315 |
vulnerable | 2026-06-08 05:41:00.137650 |
Details available
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:05:01.000Z
Updated: 2024-08-03T04:07:02.404Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-24314 |
vulnerable | 2026-06-08 05:41:00.137348 |
Details available
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:05:00.000Z
Updated: 2024-08-03T04:07:02.443Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-24313 |
vulnerable | 2026-06-08 05:41:00.137059 |
Details available
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Published: 2022-02-09T22:04:59.000Z
Updated: 2024-08-03T04:07:02.386Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-24312 |
vulnerable | 2026-06-08 05:41:00.136761 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-24311 |
vulnerable | 2026-06-08 05:41:00.136435 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-24310 |
vulnerable | 2026-06-08 05:41:00.136012 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
Contribute